Gfa door controller. 0 using the GfA-Stick and the GfA+ App.


The very wide range of functions of the control unit can be extended to include many special functions through various additional modules. Spiral cable w. Both digital and mechanical protected cable sets (to connect our drives to TS control panels) are available in the following lengths; Digital limits - 1. 6. 1 5. de Our range of automated garage doors a among the most practical garage door options available, offering smooth operation at the touch of a button availlable<\/li TS 981 door control Control panel with traffic management for GfA ELEKTROMATEN® drives with DES digital limit switch Technical data For GfA ELEKTROMATEN drives with digital limit switch DES Supply voltage: 1N~230 V, PE / 3~230 V, PE / 3N~400 V, PE / 3~400 V, PE Operating frequency: 50 Hz / 60 Hz Control voltage: 24 V DC Wireless transmission system for sensing edges, pedestrian door switches and cable tension switches, works in combination with the GfA Elektromaten door control unit TS971. Reversing contactor controls WS. 3 20. The drive unit is to be protected from rain, moisture and aggressive ambient conditions. 5 to 10. 15. Rubber profile OSE 0,2 m 11. co. The control may be used only indoors and exclusively for vertically moving doors. For High Cycles applications refer to our Carpark Solutions Replacement PCB for TS981 by GfA Elektromaten, includes cover. This means that the TS 981 also offers a solution for more complex applications. 9 230V 400V F1 = 1,6A t MOT DES/ NES S11 S12 X20 X3 2. Overview Logic Control Panel TS 981• Suitable for GfA Operators with Digital Limit Switches (DES)• UP to 3. To maintain this condition and to Aug 31, 2016 · Robert Booth of GfA explains the benefits of using a maintenance counter when you first commission a door using a TS Control Panel. GfA TS Control Panel - fault finding guide. Gfa TS 970 Pdf User Manuals. door control. Door control. 35. 7 1. Features: Protection class IP54 with CEE plug or IP65 with direct connection; integrated push button for UP-STOP-CLOSE commands; Control parameter setting via rotary selectors with Description Cover set for GfA Elektromaten control units TS959, TS970 and TS971, set consists of small and large cover part Door control TS 971 51171624_d_03. WSD door module 6. 525 x 115 mm 1 x SG40 Torque Mount (30005807) 1 x 7m XES Digital Connection Cable 1 x TS 971 Logic Controller. Overview of control 1. Doors on our factory in Warwick (4130mm wide x 4440mm high) illustrate the huge time savings that can be made using high speed drives. de GfA Elektromaten Door Control TS 971 with CEE 3N~400V (5 pole) €297. Digital limit switch DES 4 8. Gfa TS 959 Pdf User Manuals. Leading supplier of drives and controls for sectional overhead doors and roller shutters | GfA UK Ltd is the leading supplier of door drive and control Sep 29, 2016 · Peter Whittles talks through the main features and benefits of the drives and control devices offered by GfA UK. GfA specialise in drives and accessories for balanced and non-balanced roller shutters, sectional doors, fire shutters and more. e. Description: Reversing contactor control WS 900 for GfA Elektromaten drives with mechanical limit switch NES. Manuals; Brands; Door control ATEX outside Ex-Zone Hold-To-Run-Mode. OSE tester: 10. In the event of a fault on the drive unit or door control, you can use the Service Case to identify and rectify the faults in a structured manner. Brand: This control has been built in accordance with EN 12453 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements and EN 12978 Industrial, commercial and garage doors and gates - Safety devices for power operated doors - Requirements and Test methods; and left the factory in perfect condition TS 971 door control “Integrated radio“ Automatic control panel for GfA ELEKTROMATEN® drives with DES digital limit switch or NES mechanical limit switch TS 971 – Automatic control panel for DES / NES limit switches 1) Version with mains switch 2) Wireless Safety Device 3) UBS universal command sensor system (see 8. May 23, 2017 · Using a GfA high speed Fi drive means shipments can be unloaded more quickly, temperature is easier to control and heat isn’t lost or allowed to enter cooled environments. The door control unit TS971 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. Additional SAFETY DIRECTIONS Specified use The door control is intended for a power-operated door with a drive unit (GfA limit switch systems). The door control unit TS 971 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. No liability for damage May 27, 2024 · GfA ELEKTROMATEN GmbH & Co. : E250094 DC 8010 1 is a multi-functional door control for the operation of GfA door drive units recognized by UL The TS 981 from GfA Elektromaten is a comfort control unit for GfA door drives with a digital limit switch DES. Find detailed specifications and downloads for each product. Privacy Policy; Terms of use; General Terms and Conditions of Our range of automated garage doors a among the most practical garage door options available, offering smooth operation at the touch of a button availlable<\/li Local Office: 5/22 Beaumont Rd, Mount Kuring-gai NSW 2080, Australia Phone: 02 9882 2782 Email: support@gfa. This video shows you how Fault code F1. Connection cable 6,5 m for OSE 12. GfA promises reduced installation times, less on-site wiring and a single slimline one-panel solution to cope with most applications fitted with external safety and access control devices. Note A Maintenance Cycle Counter is included in the TS 971. 2 KiB) 08/2023: Door Control DC 8010 - UL Certificate of Compliance Canada (156. Installation instructions 15. 3 Specified use The door control is intended for installation in a force-actuated door that is driven by a GfA ELEKTROMATEN (door drive unit) with digital limit switch (DES). Aug 31, 2016 · GfA TS Control Panel - fault finding guide. 4mm it fits most sectional door types. KG Wiesenstraße 81 • 40549 Düsseldorf www. Overview Logic Control Panel TS 971• Suitable for Digital (DES) and Mechanical (NES) Limit Switches• UP to 3. Nov 9, 2022 · The 1000mA is an uprating option for the market-leading TS971, adding to the range, which was previously only available with 350mA. Properties: Protection class IP54; Integrated push button for UP-STOP-CLOSE commands; Parameter setting via selector switch with digital display GfA Elektromaten spare parts for door control units. Replacement circuit boards are customised components that enable the quick and efficient repair of defective or damaged control units. 0 kW Motor Power• Protection Class IP64 with Direct Connection• Supply voltage: 1x230V/N/PE; 3x230V/PE; 3x415V/N/PE; 3x415V/PE Control voltage 24V DC• Integrated OPEN-STOP-CLOSE push-button• Adjustment settings vi Industrial doors are an essential component of commercial and industrial buildings, providing security, insulation, and ease of access to a wide range of applications The Door Control Unit GfA Elektromaten TS959 is a deadman door control for GfA Elektromaten drives with digital limit switch DES or mechanical limit switch NES. 0 kW Motor Power• Protection Class IP65 with Direct Connection• Supply voltage: 1x230V/N/PE; 3x230V/PE; 3x415V/N/PE; 3x415V/PE• Dimensions 155 x 386 x 90 cm• 2 relay contact Page 1 Entrapment Protection Barrier that when obstructed stops all movement of the door. sales@gfa-elektromaten. The door control units from GfA Elektromaten in Düsseldorf are among the most frequently installed door control units in Germany. uk. TS 971 gate opener pdf manual download. 02. WS. Description: Replacement circuit board for the TS 981 from GfA Elektromaten. 6) When commissioning the Shutter set the Counter according to the Shutter Manufacturers recommendations. : 20003679 Version: 51171729_00002 2 GfA ELEKTROMATEN GmbH & Co. 5m, 3m, 5m, 7m, 9m, 13m an Roll Up Door Openers and Commercial Door Operators. Universal OSE set 0,5 m 9. 2 2. 6 KiB) 08/2023: Overview Control Panel TS 959• Suitable for GfA Operators with Mechanical or Digital Limit Switches (NES or DES)• UP to 3. The safe operation is only guaranteed with specified normal use. 8 1. Together with the GfA+ App, the tool enables reading and display of important data from GfA door controls TS Door control unit for GfA Elektromaten drives with mechanical limit switch NES, 2-contactors, control voltage 24V, with 0,8m cable and plug for the Elektromaten drive, without CEE-plug. A step-by-step guide, ideal for new fitters. The saved data is accessible at any time through the GfA-Portal. TS 959 controller pdf manual download. If the door supplier decides to operate the door with an alternative safety device (i. 2 (door with wired safety edge) on TS 971 control panel. Our range of automated garage doors a among the most practical garage door options available, offering smooth operation at the touch of a button "GfA TS959 Single The Door Control Unit GfA Elektromaten TS959 is a deadman door control for GFA Elektromaten drives with digital limit switch DES or mechanical limit switch NES. 0 kW Motor Power• Protection Class IP65 with Direct Connection• Supply voltage: 1x230V/N/PE; 3x230V/PE; 3x415V/N/PE; 3x415V/PE• Dimensions 155 x 386 x 90 cm• 2 relay contact• External supply 0. Voltcraft digital multimeter 4. 2014 0000000 0000 51171624 XXXXX. In The Box. The TS 971 control panel comes with an integrated radio receiver for 434 MHz radio products of different manufacturers. 00* plus VAT. Battery Industry Leader in High-Performance Doors | PerforMax Global GfA ELEKTROMATEN GmbH Co. Page 1 Door. com. GFA's range of industrial roller shutter door control panels is designed to meet the needs of any business, from small warehouses to large manufacturing plants. This control has been built in accordance with EN 12453 Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements; and left the factory in perfect condition from the point of view of safety. 2 20. Our range of automated garage doors a among the most practical garage door options available, offering smooth operation at the touch of a button availlable<\/li Door Control DC 8010 - UL Certificate of Compliance USA (158. Telephone: 01 926 452452 Fax: 01 926 336417 E-mail: sales@ gfa-elektromaten. 35 x 6. Need Assistance? Gfa TS 971 Pdf User Manuals. Page 3 Service Case The GfA Service Case allows you to analyse faults efficiently and cost-effectively on site. When the dock leveller is in use, the interlock inhibits the shutter from closing. No liability for damage GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. Frequency 2,4 GHz, in IP65 rated enclosure, incl. 2 X2 X5 S F1 V1 S13 X1 X1 DES/ NES DES or NES limit switch socket X1 Mains supply X2 Door safety switch F1 Micro-fuse 1. Sign up for updates and information . 5 m wide 10. All settings are saved in the GfA cloud per internet as an option. photo beam), then an end of Here’s a simple way to program your radio remotes into the TS 971 by GFA Elektromaten; for a more relaxed operation of your door. Resistor 8k2 14. Our controller monitors a functional Safety Edge and will only permit automatic closing if the controller receives a valid test signal from the safety edge sensor. in stock Add to shopping cart Page 1 Installation instructions Door control TS 959 Hold-to-run control Version: 51171547 – en – Status: j / 01. We have 1 GFA DC 8010 manual available for free PDF download: Installation Instructions Manual GFA DC 8010 Installation Instructions Manual (55 pages) Door Control Unit In this video Howard Weaver walks you through how to set up a GfA TS Control Panel. This video explains what the fault code means and how you can rectify the Page 1 Installation instructions Door control TS 971 51171521 a 02. 60 FI - Manual Tech tip for door fitters and maintenance engineers who encounter fault code F1. No liability for damage 2. Here, you will find information on each of our available operators. Under the brand name ELEKTROMATEN, we sell around 200,000 drive units and 150,000 door controls worldwide every year. 091) Housing TS 971 door control “Integrated radio“ Automatic control panel for GfA ELEKTROMATEN® drives with DES digital limit switch or NES mechanical limit switch TS 971 Type test according to: DIN EN 12453 DIN EN 12978 DIN EN 60335-2-103 DIN EN ISO 13849-1 TÜV NORD CERT GmbH Approvals and certificates . 35 A @ 24 V DC and Status displays of the door control The display of the door control consists of a double- digit seven-segment-display. A step-by-step guide, ideal for new fit The door control unit TS 971 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. Oct 16, 2021 · The GfA dock leveller control (GfA LB 700) with a GfA TS control panel and designed to control dock levellers and these are interlocked in such a way so that the dock leveller cannot be operated unless the door is in the fully open position. i NOTE An E alternating with a number on the door control stands for a movement command. GfA-Stick 3. The entrapment protection RAYTECTOR is suitable for doors between 1. 5 20. This video explains what the fault code means and how you can rectify the GfA UK Ltd | 1,534 followers on LinkedIn. How fast you want it to open, how many times a day will it cycle and if there is power available are just a few of these factors. There are good reasons for this - pre-assembled connection cables to the Elektromaten drive and a comprehensible and simple program guide ensure easy installation and commissioning. A complete range of door controls including bespoke panels for specific applications. Peter Whittles talks through the main features and benefits of the drives and control devices offered by GfA UK. 25. The door control is then switched by a programming command to communication mode Nov 10, 2022 · A new 1000mA TS 971 GfA recommends Safety Edge Installation for self closing doors. 2 The door control is intended for a power-operated door with a drive unit (NES/DES GfA limit Door controls TS . Rectifier EGR II 13. (See Control Programming 8. Bluetooth® 4. KG Wiesenstrae 81 40549 Dsseldorf Germany +49 (0) 211 500 90 0 +49 (0) 211 500 90 90 www. 1. 2020 0 0 00 0 00 00 0 0 5 11 7 15 4 7 XXXXX; Page 2 GfA ELEKTROMATEN GmbH & Co. The door control is intended for a power-operated door with a drive unit (NES/DES GfA limit switch system). de GfA Elektromaten manufactures operators and controllers for industrial and building doors. 35 x 115 mm 1 x Steel Key 6. 2012; Page 2 GfA - Gesellschaft für Antriebstechnik GmbH Wiesenstraße 81 D-40549 Düsseldorf www. SE 8. See just how quickly a door will move using Apr 4, 2018 · The combined dock leveller uses the GfA dock leveller control (LB 700) with a TS control panel and these are interlocked in such a way so that the dock leveller cannot be operated unless the door is in the fully open position. 35 x 9. KEY ADVANTAGES Integrated Safety Brake inside the Gearbox Solutions up to 1800 Nm Full Logic, No Expansion Board required No Handing 2 Year Warranty Designed for Australia - Made in Germany These products are rate for Standard Cycles. The TS971 control panel comes with an integrated radio receiver for 434 MHz radio products of different manufacturers. All of these details are cov TS 981 – Control panel with traffic management for DES TS 981 door control Control panel with traffic management for GfA ELEKTROMATEN® drives with DES digital limit switch Technical data For GfA ELEKTROMATEN drives with digital limit switch DES Supply voltage: 1N~230V, PE / 3~230V, PE / 3N~400V, PE / 3~400V, PE Operating frequency: 50 / 60 Hz The door control unit TS 971 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. 5 and 8. GfA TS Control Panel range. 2012 Status: 22. Explore GfA door drives and control equipment for a wide range of applications. GfA dock leveller controls are designed for efficient and user-friendly operation of dock levellers with hinged wedge lip or extendible lip. au Office Hours: Monday - Friday / 8:00 am - 5:00 pm Aug 31, 2016 · Tech tip for door fitters and maintenance engineers who encounter fault code F3. Door control ATEX outside Ex-Zone Hold-To-Run-Mode. KG is a full-range supplier of drive systems for industrial doors. TS 959 door control Hold-to-run control panel for GfA-ELEKTROMATEN® drives with DES digital limit switch or NES mechanical limit switch TS 959 Type test according to: DIN EN 12453 DIN EN 12978 DIN EN 60335-2-103 DIN EN ISO 13849-1 TÜV NORD CERT GmbH Approvals and certificates TS 959 – Hold-to-run control panel for DES / NES limit switches The door control unit TS 970 by GfA Elektromaten is an automatic control panel for use with GfA Elektromaten drives with digital (DES) or mechanical (NES) limit switch system. Copyright 2024 © GfA-Elektromaten. Nov 10, 2022 · A new 1000mA TS 971 has been launched by industrial door drive specialist, GfA UK Ltd. In this video Howard Weaver walks you fault code F1. Support. gfa-elektromaten. 1 x SE 8. All drives are manufactured in Germany. 16 GfA ELEKTROMATEN UK Ltd Unit 1, Titan Business Centre, Spartan Close Warwick CV34 6RR, England. 2022_G ) 4 e o: UL 325 No. The replacement circuit board is supplied with a cover for direct installation in the existing control unit housing. Music: Skyline- Text Me Records Explore GfA door drives and control equipment for a wide range of applications. Properties: For Roller Shutter doors that are counter balanced and fitted with a separate safety brake, and either chain or gear transmission View and Download GFA TS 971 installation instructions manual online. View online or download Gfa TS 971 Manual. In addition to the standard "extend and retract" functions, programmable relay contacts allow for numerous safety functions and other additional functions. Brand: Door control. The drive by GfA Elektromaten comes with 90Nm of torque, 24 rpm and with a hollow-shaft diameter of 25. automatic control panel with radio. 2 for doors with a wireless safety edge GfA TS Control Panel. 2 for doors with a wired safety edge GfA TS Control Panel. Sign In Upload. 6 1. 2 or 3 contactors; Control voltage: 24V Maximum Door Weight (Kg): 300 Medium Cycle: 20 cycles/hr Rating IP65* Controller: TS 971 Logic / Built in receiver. de ( info@gfa-elektromaten. 24 and door control unit TS970 is the perfect choice for automating counter balanced doors. 60 Operator 1 x Steel Key 6. 0 kW Motor Power• Protection Class IP64 with Direct Connection• Supply voltage: 1x230V/N/PE;3x230V/PE; 3x415V/N/PE; 3x415V/PE• Integrated OPEN-STOP-CLOSE push-button• Adjustment settings via selecto The set of GfA Elektromaten door drive SE9. 43. 0 using the GfA-Stick and the GfA+ App. Overview Logic Control Panel TS 971-1000mA• Suitable for high-speed doors• Suitable for Digital (DES) and Mechanical (NES) Limit Switches• UP to 3. 1 1. de info@gfa-elektromaten. junction box 7. All of these details are covered in the product instruction here Overview Logic Control Panel TS 971 BoardExcludes controller housing Support TS 971 | Manual Retired GfA Controller Replacements Sectional Door Products The GfA Stick fits into the limit switch connection of your TS door control. Door control TS 971 5. There are many factors to consider when choosing how your door will operate. 1 959 3. The GfA-Stick plugs into the TS door controls limit switch port. Typical applications include: · Roller shutters · Rolling grilles · Sectional doors · High speed doors · Vertical lift doors · Folding doors Installation-/ Operating instructions Door control TS 971-Ex for use in ATEX; zone 1 & 2 / zone 21 & 22 Part no. View online or download Gfa TS 970 Installation Instructions Manual, Electrical Wiring Instructions. Features: Protection class IP54 with CEE plug or IP65 with direct connection; integrated push button for UP-STOP-CLOSE commands; Control parameter setting via rotary selectors with Aug 31, 2016 · In this video GfA's Robert Booth walks you through how to programme a remote control on the GfA TS 971 Control Panel. View online or download Gfa TS 959 Installation Instructions Manual, Electrical Wiring Instructions. The display can show symbols, letters, or numbers. See just how quickly a door will move using an Fi drive and understand the how safety edges and photo beams keep users safe and the door in good working order. de 1 2 3 DC 8010 09. The figure shows the display when all segments are illuminated. By understanding the features of each model and how to troubleshoot common issues, you can ensure your industrial doors operate effectively and securely. 6 A time-lag X3 Emergency STOP control device MOT Motor socket X5 Control device, external Industrial door control Controller GFA TS 971 Installation Instructions Manual 68 pages Door control. uk Dec 18, 2018 · A new Fault Guide for TS Door Controls is now available 1. Founded in Düsseldorf in 1954, around 250 people are currently employed at the site. GfA door control panels used with GfA ELEKTROMATEN are high-performance drive systems for nearly all door types. GFA Elektromaten offers a comprehensive range of spare parts for door control units, including replacement circuit boards and replacement housings. hh px hf ri dk ev vt oj xc fv